Skip to content

Why is my auxiliary heat always on?

Published 3 min read

What does auxiliary heat actually do?

A heat pump doesn’t make heat. It moves heat from the outdoor air into your house. That works well across most of a Hampton Roads winter, but as the temperature outside drops, there’s less heat to collect and the heat pump has to work harder for the same result.

Auxiliary heat is a set of electric heating elements inside the indoor air handler. When the heat pump can’t keep up on its own (on a very cold morning, or while the outdoor coil is defrosting), the thermostat brings those elements on to help. Then it shuts them off again.

What’s the difference between auxiliary and emergency heat?

They’re the same heating elements. The difference is who turns them on. Auxiliary heat comes on automatically, alongside the heat pump, when the system needs help. Emergency heat is a setting you choose on the thermostat, and it runs the elements alone with the heat pump off.

Emergency heat is meant for exactly what it sounds like: the heat pump has failed and you need to stay warm until it’s repaired. It isn’t a setting to leave on.

Why would it run all the time?

When auxiliary heat runs through ordinary winter weather, it’s usually covering for something. The most common causes we find:

  • Low refrigerant. A heat pump that’s low on refrigerant has a leak somewhere, and it can’t move as much heat. The backup fills the gap.
  • A defrost problem. If the outdoor coil ices over and the defrost cycle isn’t clearing it, the heat pump loses most of its capacity.
  • Thermostat staging. Some thermostats are set to bring backup heat on whenever the house is a degree or two behind, rather than letting the heat pump catch up.
  • Airflow. A clogged filter, a weak blower, or restrictive ductwork keeps the heat pump from delivering what it produces.
  • Sizing. A heat pump that was undersized for the house will lean on backup heat every cold night.

Can I fix it myself?

Some of it. Replace the filter if it’s dirty, make sure the thermostat is set to “heat” rather than “emergency heat,” and check that the outdoor unit isn’t buried in leaves or encased in ice that won’t clear. If you have a programmable thermostat, large overnight setbacks can also trigger backup heat in the morning.

Past that (refrigerant, defrost controls, sensors, and thermostat staging), it’s a job for a technician.

FAQ

More questions about auxiliary heat

Is it normal for auxiliary heat to come on during defrost?

Yes. When the heat pump reverses briefly to melt frost off the outdoor coil, auxiliary heat often comes on so the air coming out of the vents doesn’t feel cold. It should shut off again when defrost ends.

Should I set my heat pump thermostat back at night?

Keep them small. Large overnight setbacks can trigger backup heat in the morning, and auxiliary heat costs considerably more to run than the heat pump itself. A degree or two is usually enough.

Does a heat pump work in a Hampton Roads winter?

Yes. It works well across most of a Hampton Roads winter. As the temperature drops there’s less heat to collect, so auxiliary heat helps on very cold mornings and while the outdoor coil is defrosting.

Want someone to look at it?

We’ll find what’s actually wrong and explain your options in plain English, and if it can be fixed, that’s what we’ll recommend.